Free Consultation
info@elitasrcs.com | ➀ +91-9076611766 ➁ +91-9076611767
Mandatory

BIS Certification for
DC supplied/ battery-operated Massage appliances IS 302 Part 1: 2024/IEC 60335-1

IS 302 Part 1:2024/IEC 60335-1

BIS Certification for DC Supplied/Battery-Operated Massage Appliances is mandatory under IS 302 (Part 1): 2024/IEC 60335-1, requiring manufacturers to obtain an ISI mark via the Bureau of Indian Standards to lawfully import, produce, or sell these goods in India. Compliance with IS 302 (Part 1): 2024/IEC 60335-1, which specifies general safety requirements for household and similar electrical appliances, helps protect users against electrical shock, overheating, fire hazards, mechanical risks, battery-related hazards, and other potential safety issues.

 

All manufacturers and importers intending to trade in battery-operated or DC-operated massage units in India should comply with prescribed BIS standards. Obtaining a BIS certificate ensures conformity with regulations, improves product quality, and builds consumer confidence by indicating adherence to safety measures and global standards in the manufacturing process.

 

Testing Parameters for DC Supplied/ Battery-Operated Massage Appliances IS 302 Part 1

The requirements of IS 302 (Part 1): 2024 / IEC 60335-1, which include the safety against electric shocks and charging of metal-ion batteries and heating under abnormal conditions, are obligatory under the Bureau of Indian Standards (BIS).

  • Protection from electric shock: The ability to reach electrified areas and the reliability of insulation should be evaluated.
  • Temp and Heat Generation: Measurement of the temperature of components in operation during their use.
  • Leakage current and dielectric strength: The device is going to be applied for dielectric tests i.e. the device will be used in operation.
  • Malfunctioning: The working of device must be simulated for jammed rotor, defective elements or short circuits.
  • Safety of battery charging: In order to determine properly the state of the internal battery as it is mentioned in provision 12.
  • PELV circuits: Compliance with safety requirements in Protected Extra Low Voltage circuits.
  • Moisture resistance: Testing of the enclosure against sweat, water and disinfectants.
  • Label and guidelines: Verifying availability of warnings, indication marks and recommendations on safe operation of the product.

 

BIS Certification Process for DC Supplied/ Battery-Operated Massage Appliances in India

Obtaining BIS Certification for DC supplied/ battery-operated Massage appliances in India requires sample testing to be conducted in a lab accredited by BIS, application submission on the website of the manakonline portal, and factory compliance check of the manufacturing unit. 

  • BIS Certification Process for Indian Manufacturers
  • BIS Certification Process for Foreign Manufacturers

 

BIS Certification Cost for DC Supplied/ Battery-Operated Massage Appliances (2026)

The BIS Certification cost for DC Supplied/ Battery-Operated Massage Appliances is given below: 

S No.

Particular

Amount (INR)

Remarks

1.

Application Fee

1000 

To be paid directly to BIS 

2.

Audit Fee

7000

To be paid directly to BIS 

3.

License Fee

1000

To be paid directly to BIS 

4.

Sample Testing Fee

As Applicable

To be paid directly to BIS (Testing charges vary by product and lab).

5.

Minimum Advance Marking Fee

As per actual

To be paid directly to BIS (Marking fee varies as per Indian Standard)

6.

Renewal Fee

1000

To be paid directly to BIS 

7.

Inclusion Fee

5000

To be paid directly to BIS 

8.

ERCS Pvt Ltd Service Fee

Please contact info@elitasrcs.com

 

Why Choose ERCS as Your BIS Certification Consultant for DC Supplied/ Battery-Operated Massage Appliances?

Selecting ERCS Private Limited to be your compliance partner guarantees smooth compliance with BIS Scheme-I (ISI Mark) mandatory certification in accordance with IS 302 (Part 1):2024. They provide technical documentation help, lab testing coordination, and factory audit preparation. 

  • In-Depth Technical Expertise: Comprehensive understanding of safety and performance requirements for battery-operated and DC-supplied appliances under Indian Standards. 
  • End-to-End Project Management: Complete handling of application filing, paperwork, and liaison through the ManakOnline portal. 
  • Laboratory Testing Coordination: Seamless sample testing alignment with BIS-recognized and NABL-accredited testing labs. 
  • Factory Audit Readiness: Professional guidance for manufacturing plant inspections, quality control assessment, and non-conformity corrections.
  • Support for Indian & Foreign Manufacturers: Tailored certification solutions for both domestic and overseas businesses.
  • Transparent Consultancy: Regular updates and dedicated project support throughout the process.
  • Post-Certification Services: Assistance with licence renewal, amendments, and ongoing compliance.
  • Trusted BIS Consultant: Reliable expertise to help you achieve hassle-free BIS certification.
Need Compliance Help?

Fill out the form below and one of our regulatory experts will contact you shortly.