GET BIS CERTIFICATION FOR UNPLASTICIZED POLYVINYL CHLORIDE (PVC-U) PIPES FOR SOIL AND WASTE DISCHARGE SYSTEM FOR INSIDE AND OUTSIDE BUILDINGS INCLUDING VENTILATION AND RAIN WATER SYSTEM IS 13592:2013
PVC-U is short for Unplasticized PVC, meaning no plasticizer has been added to the PVC compound. Unplasticized PVC is also known as rigid PVC.
PVC-U is the most common PVC type for pipes and fittings including transportation of drinking water, soil and waste, sewage and underground drainage and other industrial applications.
Pipes and fittings made of PVC-U have many benefits. They are a safe choice for various industrial applications, light and easy to handle and affordable.
Technical properties include high mechanical performance, high durability (at least 100 years for underground pipes), high chemical resistance and resistance to UV exposure. Moreover, PVC-U pipes have favorable environmental profiles and are 100% recyclable.
BIS is a statutory institution established under the Bureau of Indian Standards Act,1986 to promote harmonious development of the activities of standardization, marking and quality certification of goods and attending to connected matters in the country.
Unplasticized polyvinyl chloride (PVC-U) pipes for soil and waste discharge system for inside and outside buildings including ventilation and rain water system product has been specified in IS 13592:2013 by Bureau of Indian Standards.
SCOPE :
This standard covers requirements for plain and socket end unplasticized polyvinyl chloride (PVC-U) pipes with nominal outside diameters 40 mm to 315 mm for use for soil and waste discharge system inside and outside buildings including ventilation, rain water and rain water harvesting applications.
REFERENCES :
The following Indian Standards contain provisions, which through reference in this text constitute provisions of this standard. At the time of publication, the editions indicated were valid. All standards are subject to revision and parties to agreement based on this standard are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below.
IS No. Title
4669 : 1968 Methods of test for polyvinyl chloride resins
4905 : 1968 Methods for random sampling
4985 : 2000 Unplasticized PVC pipes for potable water supplies - Specification
12235 Thermoplastics pipes and fittings - Methods of test:
(Part 1) : 2004 Measurement of dimensions
(Part 2) : 2004 Determination of vicat softening temperature
(Part 5) : 2004 Longitudinal reversion
(Part 6) : 2004 Stress relief test
(Part 7) : 2004 Resistance to sulphuric acid
(Part 8) : 2004 Resistance to internal hydrostatic pressure
(Part 9) : 2004 Resistance to external blows (impact resistance) at 0°C (round-the-clock method)
(Part 11) : 2004 Resistance to dichloromethane at specified temperature
(Part 13) : 2004 Determination of tensile strength and elongation
14182 : 2004 Solvent cement for use with polyvinyl chloride pipes and fittings
RAW MATERIALS :
· PVC resin and additives – Clause 6 of IS 13592
TESTING PARAMETERS :
· Colour of pipes
· Materials
· Dimensions
· Visual Appearance
· Reversion Test
· Stress relief test
· Vicat softening temperature
· Effect of sunlight